thermal: cellular mitigation on critical battery

Enable cellular mitigation on critical battery condition.

Bug: 181572536
Test: Local Test
Signed-off-by: George Lee <geolee@google.com>
Change-Id: I310c3b67bc6a7f83a724005665eeda50b29469f7
This commit is contained in:
George Lee 2021-03-08 09:28:34 -08:00
parent cd5aaf7fdf
commit 1dbbc0a53b
4 changed files with 116 additions and 0 deletions

View file

@ -295,6 +295,35 @@
"Multiplier":1, "Multiplier":1,
"Monitor":false "Monitor":false
}, },
{
"Name":"critical-battery-cell",
"Type":"BCL_VOLTAGE",
"VirtualSensor":true,
"Formula":"COUNT_THRESHOLD",
"TriggerSensor": "vdroop1",
"Combination":[
"battery",
"battery_cycle",
"vdroop1"
],
"Coefficient":[
"-10000",
"400",
"1200"
],
"HotThreshold":[
"NAN",
"NAN",
"NAN",
"NAN",
"NAN",
3.00,
"NAN"
],
"VrThreshold":"NAN",
"Multiplier":1,
"Monitor":true
},
{ {
"Name":"FLASH_LED_REDUCE", "Name":"FLASH_LED_REDUCE",
"Type":"UNKNOWN", "Type":"UNKNOWN",

View file

@ -295,6 +295,35 @@
"Multiplier":1, "Multiplier":1,
"Monitor":false "Monitor":false
}, },
{
"Name":"critical-battery-cell",
"Type":"BCL_VOLTAGE",
"VirtualSensor":true,
"Formula":"COUNT_THRESHOLD",
"TriggerSensor": "vdroop1",
"Combination":[
"battery",
"battery_cycle",
"vdroop1"
],
"Coefficient":[
"-10000",
"400",
"1200"
],
"HotThreshold":[
"NAN",
"NAN",
"NAN",
"NAN",
"NAN",
3.00,
"NAN"
],
"VrThreshold":"NAN",
"Multiplier":1,
"Monitor":true
},
{ {
"Name":"FLASH_LED_REDUCE", "Name":"FLASH_LED_REDUCE",
"Type":"UNKNOWN", "Type":"UNKNOWN",

View file

@ -102,6 +102,35 @@
"Multiplier":0.001, "Multiplier":0.001,
"Monitor":false "Monitor":false
}, },
{
"Name":"critical-battery-cell",
"Type":"BCL_VOLTAGE",
"VirtualSensor":true,
"Formula":"COUNT_THRESHOLD",
"TriggerSensor": "smpl_gm",
"Combination":[
"battery",
"battery_cycle",
"smpl_gm"
],
"Coefficient":[
"-10000",
"400",
"1400"
],
"HotThreshold":[
"NAN",
"NAN",
"NAN",
"NAN",
"NAN",
3.00,
"NAN"
],
"VrThreshold":"NAN",
"Multiplier":1,
"Monitor":true
},
{ {
"Name":"FLASH_LED_REDUCE", "Name":"FLASH_LED_REDUCE",
"Type":"UNKNOWN", "Type":"UNKNOWN",

View file

@ -102,6 +102,35 @@
"Multiplier":0.001, "Multiplier":0.001,
"Monitor":false "Monitor":false
}, },
{
"Name":"critical-battery-cell",
"Type":"BCL_VOLTAGE",
"VirtualSensor":true,
"Formula":"COUNT_THRESHOLD",
"TriggerSensor": "smpl_gm",
"Combination":[
"battery",
"battery_cycle",
"smpl_gm"
],
"Coefficient":[
"-10000",
"400",
"1400"
],
"HotThreshold":[
"NAN",
"NAN",
"NAN",
"NAN",
"NAN",
3.00,
"NAN"
],
"VrThreshold":"NAN",
"Multiplier":1,
"Monitor":true
},
{ {
"Name":"FLASH_LED_REDUCE", "Name":"FLASH_LED_REDUCE",
"Type":"UNKNOWN", "Type":"UNKNOWN",