thermal: update thermal policy according to the new CPU dvfs
Bug: 281740658 Test: emul_severity Change-Id: I76686421764e2dfae3de9be78ef16a1c3dee9e70
This commit is contained in:
parent
dd1bbd007e
commit
6c12db400a
2 changed files with 8 additions and 8 deletions
|
@ -450,8 +450,8 @@
|
|||
"MaxReleaseStep": 1,
|
||||
"MaxThrottleStep": 2,
|
||||
"BindedPowerRail": "S2M_VDD_CPUCL2",
|
||||
"CdevCeiling": [0, 13, 13, 13, 13, 15, 15],
|
||||
"LimitInfo": [0, 0, 0, 0, 13, 15, 15]
|
||||
"CdevCeiling": [0, 12, 12, 12, 12, 14, 14],
|
||||
"LimitInfo": [0, 0, 0, 0, 12, 14, 14]
|
||||
}
|
||||
]
|
||||
},
|
||||
|
@ -505,8 +505,8 @@
|
|||
"MaxReleaseStep": 1,
|
||||
"MaxThrottleStep": 2,
|
||||
"BindedPowerRail": "S2M_VDD_CPUCL2",
|
||||
"CdevCeiling": [0, 13, 13, 13, 13, 15, 15],
|
||||
"LimitInfo": [0, 0, 0, 0, 13, 15, 15]
|
||||
"CdevCeiling": [0, 12, 12, 12, 12, 14, 14],
|
||||
"LimitInfo": [0, 0, 0, 0, 12, 14, 14]
|
||||
},
|
||||
{
|
||||
"CdevRequest": "thermal-gpufreq-0",
|
||||
|
|
|
@ -427,8 +427,8 @@
|
|||
"MaxReleaseStep": 1,
|
||||
"MaxThrottleStep": 2,
|
||||
"BindedPowerRail": "S2M_VDD_CPUCL2",
|
||||
"CdevCeiling": [0, 13, 13, 13, 13, 15, 15],
|
||||
"LimitInfo": [0, 0, 0, 0, 13, 15, 15]
|
||||
"CdevCeiling": [0, 12, 12, 12, 12, 14, 14],
|
||||
"LimitInfo": [0, 0, 0, 0, 12, 14, 14]
|
||||
}
|
||||
]
|
||||
},
|
||||
|
@ -482,8 +482,8 @@
|
|||
"MaxReleaseStep": 1,
|
||||
"MaxThrottleStep": 2,
|
||||
"BindedPowerRail": "S2M_VDD_CPUCL2",
|
||||
"CdevCeiling": [0, 13, 13, 13, 13, 15, 15],
|
||||
"LimitInfo": [0, 0, 0, 0, 13, 15, 15]
|
||||
"CdevCeiling": [0, 12, 12, 12, 12, 14, 14],
|
||||
"LimitInfo": [0, 0, 0, 0, 12, 14, 14]
|
||||
},
|
||||
{
|
||||
"CdevRequest": "thermal-gpufreq-0",
|
||||
|
|
Loading…
Add table
Add a link
Reference in a new issue