note: add smartfeature.gstf that only used for Hotword
pipeline in AoC which is sharing to chre usage too.
On ZUMA
CHRE PDM Gain(gain=10)
CHRE AEC Gain(gain=-22)
CHRE SRC AEC Timeout(timeout=300000)
This table also contains hotword gain control as
Non Eraser gain (gain=220)
Eraser Post Gain (gain=220)
Test: end-to-end verify by CHRE
using aoc_audio_cfg to query gain as below
adb shell aoc_audio_cfg hotword_get_non_eraser_gain
adb shell aoc_audio_cfg hotword_get_eraser_post_gain
Bug: 271078701
Change-Id: I8355563141b86c59e0c9115a64b787ac92f5aadd
The change item are template.xml and recording.gatf which could be found in the ZIP file.
For template.xml: add ID73~ID80 in the new WNR library
For recording.gatf: update MBDRC MIC path : MBDRC Threadhold_dB[1] 44/44/44 (Band1/Band2/Band3) MBDRC gain_dB 27 Limiter gain -2
Camcorder path : MBDRC Threadhold_dB[1] 44/38/38 (Band1/Band2/Band3) MBDRC gain_dB 24 Limiter gain 0 KneeWidth[2] 6 -> 0 Limiter_gain_dB -2 -> -0.2
Bug: 265884472
Test: verified by HW jacky
Change-Id: I8e01794556437fa6b74e0ca6e972778272741717
Signed-off-by: yixuanjiang <yixuanjiang@google.com>
The change item is recording.gatf which could be found in the ZIP file.
for recording.gatf
change parameter for MBDRC in all scenarios
Mackup_gain_dB 24 -> 27.0
Min_Gain_dB -25 -> -29.0
Threadhold_dB[1] -44 -> -38
CompressRatio [1]0.8 -> 1.0
CompressRatio [2]0.2 -> 0.0
KneeWidth[2] 0 -> 6
Limiter_gain_dB -0.2 -> -2
Change IIR2 8kHz to 2dB
Test: verified by HW wjacky@
Bug: 264746360
Change-Id: Icb53d0429fe8adab43a1743bedb71ee81eafd947
Signed-off-by: yixuanjiang <yixuanjiang@google.com>
There are recording.gatf and template.xml in the ZIP file.
for recording.gatf
Camcorder path : IIR1(high pass), SUR(calibrated filter), IIR2(high pass), AGC (-24 ideal RMS), MBDRC ( -44 threshold)
MIC path: correct MBDRC
for template.xml
correct SUR module ID
Files from the latest attachment on b/263448513
Bug: 263448513
Test: verified by wjacky@
Change-Id: I7d7dc2496ee3cf37b35b30f34b9f72febc512189