battery: disable wireless for pts battery test
Disable wireless charging during drain, usb charging, and charger stress test - vendor.disable.wlc 1 If a device was put on dreamliner and shut dwon(drain out), it powered up by DC_CHG and then shut down(0%) again - boot (by DC_CHG) continuously. To avoid this symptom, limit wireless current_max as 75000 after devices boot up - persist.vendor.limit.wlc.current=1 How to verify: adb shell setprop vendor.disable.wlc 1 adb shell cat /sys/class/power_supply/wireless/online >>>> 0 adb shell setprop persist.vendor.limit.wlc.current 1 adb shell cat /sys/class/power_supply/dc/current_max >>>> 75000 Bug: 179094447 Test: set the property manually and query the result from file node. Change-Id: Ic5791c53f735caa19c73bae750651d774c0d4615 Signed-off-by: Ken Tsou <kentsou@google.com> (synced from commit 84d73dafb7e44bd195adcc4cbb16bad28728aedc)
This commit is contained in:
parent
80f0a6d3d0
commit
7f6e0eee36
1 changed files with 24 additions and 0 deletions
24
init.hardware.wlc.rc.userdebug
Normal file
24
init.hardware.wlc.rc.userdebug
Normal file
|
@ -0,0 +1,24 @@
|
|||
#
|
||||
# Copyright (C) 2018 The Android Open-Source Project
|
||||
#
|
||||
# Licensed under the Apache License, Version 2.0 (the "License");
|
||||
# you may not use this file except in compliance with the License.
|
||||
# You may obtain a copy of the License at
|
||||
#
|
||||
# http://www.apache.org/licenses/LICENSE-2.0
|
||||
#
|
||||
# Unless required by applicable law or agreed to in writing, software
|
||||
# distributed under the License is distributed on an "AS IS" BASIS,
|
||||
# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
|
||||
# See the License for the specific language governing permissions and
|
||||
# limitations under the License.
|
||||
#
|
||||
|
||||
on property:sys.boot_completed=1 && property:persist.vendor.limit.wlc.current=1
|
||||
write /sys/class/power_supply/dc/current_max 75000
|
||||
|
||||
on property:sys.boot_completed=1 && property:persist.vendor.limit.wlc.current=0
|
||||
write /sys/class/power_supply/dc/current_max 1100000
|
||||
|
||||
on property:vendor.disable.wlc=1
|
||||
write /sys/class/power_supply/wireless/online 0
|